[vc_row fullwidth=”yes” top_margin=”0″ bottom_margin=”0″ css=”.vc_custom_1582650757236{margin-top: 0px !important;margin-right: 0px !important;margin-bottom: 0px !important;margin-left: 0px !important;padding-top: 40px !important;padding-right: 0px !important;padding-bottom: 20px !important;padding-left: 0px !important;}” background_color=”#f1f1f1″][vc_column css=”.vc_custom_1462144217528{margin-top: 0px !important;margin-bottom: 0px !important;}”][vc_custom_heading text=”Instructions – M40 Muscle Sense™” font_container=”tag:h4|font_size:28px|text_align:center|color:%23111111|line_height:42px” google_fonts=”font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:300%20light%20regular%3A300%3Anormal” css=”.vc_custom_1787000437363{margin-bottom: 5px !important;padding-top: 10px !important;}”][vc_custom_heading text=”Model M40 is water-resistant – not waterproof. Do not submerge.” font_container=”tag:p|font_size:18px|text_align:center|color:%23111111|line_height:24px” google_fonts=”font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:300%20light%20regular%3A300%3Anormal” css=”.vc_custom_1787323530487{margin-right: 0px !important;margin-bottom: 20px !important;margin-left: 0px !important;border-right-width: 0px !important;border-left-width: 0px !important;padding-right: 0px !important;padding-left: 0px !important;}”][vc_row_inner gap=”35″ css=”.vc_custom_1597080098802{margin-right: 30px !important;padding-top: 40px !important;}”][vc_column_inner el_class=”my-column-limit-min-width” width=”1/3″ css=”.vc_custom_1787149626309{margin-right: 30px !important;margin-left: 30px !important;}”][vc_custom_heading text=”1. Charge” font_container=”tag:p|font_size:20px|text_align:left|color:%23111111|line_height:32px” google_fonts=”font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:400%20regular%3A400%3Anormal” css=”.vc_custom_1787069683735{margin-bottom: 10px !important;}”][vc_column_text css=””]
Connect
| Charger | USB (all) |
| Cable | USB-C (all) |
LED (on M40)
| Red | Charging (3-4 hours) |
| Green | Charged (16-24 hour run time) |
[/vc_column_text][vc_separator css=””][vc_custom_heading text=”2. Download App” font_container=”tag:p|font_size:20px|text_align:left|color:%23111111|line_height:32px” google_fonts=”font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:400%20regular%3A400%3Anormal” css=”.vc_custom_1787053930467{margin-bottom: 0px !important;}”][vc_custom_heading text=”Muscle View by ANR Corp” font_container=”tag:p|font_size:14px|text_align:center|color:%23111111|line_height:24px” google_fonts=”font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:300%20light%20regular%3A300%3Anormal” css=”.vc_custom_1787054796920{margin-bottom: 20px !important;}”][vc_column_text css=””]Follow one of these links for your free app:
[/vc_column_text][vc_single_image image=”58″ img_size=”200×63″ add_caption=”yes” onclick=”custom_link” img_link_target=”_blank” css=”” el_class=”store-buttons” link=”https://apps.apple.com/us/app/anr-muscle-monitor/id1484269901?mt=8″][vc_single_image image=”59″ img_size=”200×63″ add_caption=”yes” onclick=”custom_link” img_link_target=”_blank” css=”.vc_custom_1786971664259{padding-top: 0px !important;}” el_class=”store-buttons” link=”https://play.google.com/store/apps/details?id=com.anrcorp.muscleview”][/vc_column_inner][vc_column_inner el_class=”my-column-limit-min-width” width=”1/3″ css=”.vc_custom_1787149633443{margin-right: 30px !important;margin-left: 30px !important;}”][vc_custom_heading text=”3. Apply” font_container=”tag:p|font_size:20px|text_align:left|color:%23111111|line_height:32px” google_fonts=”font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:400%20regular%3A400%3Anormal” css=”.vc_custom_1787071316913{margin-bottom: 10px !important;}”][vc_custom_heading text=”with Adhesive Electrodes” font_container=”tag:p|font_size:18px|text_align:left|color:%23111111|line_height:20px” google_fonts=”font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:400%20regular%3A400%3Anormal” css=”.vc_custom_1787090060189{margin-bottom: 10px !important;}”][vc_column_text css=””]
Prepare skin at target site
- Clean, dry, and oil free
- Shaving required only if body hair is thick
Load Electrodes
- Take 2 fresh electrodes from foil envelope (included in kit)
- Snap into M40. Remove backing.
Secure M40 on body
- Place in-line with muscle to be measured
- Press firmly to skin while contracting muscle
For best results
- Do not re-use electrodes and avoid relocating. (every application weakens adhesive strength and signal quality)
- Additional ECG snap electrodes can be purchased at most medical supply stores and anrcorp.com
[/vc_column_text][vc_custom_heading text=”with Non-Adhesive Electrodes” font_container=”tag:p|font_size:18px|text_align:left|color:%23111111|line_height:20px” google_fonts=”font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:400%20regular%3A400%3Anormal” css=”.vc_custom_1787090067830{margin-bottom: 10px !important;}”][vc_column_text css=””]
Load Electrodes
- Snap 2 Metal EMG Contacts into M40
Secure M40 on body
- Place in-line with muscle to be measured
- Overwrap sensor with strong stretchable strap
- at least 2 inch wide (3 preferred)
- cinch style with hook&loop closure
For best results
-
- Use on limbs
- Use a wide strap (fully entrap M40)
- Secure M40 tightly over muscle
[/vc_column_text][/vc_column_inner][vc_column_inner el_class=”my-column-limit-min-width” width=”1/3″ css=”.vc_custom_1787149641110{margin-right: 30px !important;margin-left: 30px !important;}”][vc_custom_heading text=”4. Measure” font_container=”tag:p|font_size:20px|text_align:left|color:%23111111|line_height:32px” google_fonts=”font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:400%20regular%3A400%3Anormal” css=”.vc_custom_1787071466960{margin-bottom: 10px !important;}”][vc_custom_heading text=”Open ANR Muscle View App” font_container=”tag:p|font_size:18px|text_align:left|color:%23111111|line_height:20px” google_fonts=”font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:400%20regular%3A400%3Anormal” css=”.vc_custom_1787147724832{margin-bottom: 10px !important;}”][vc_column_text css=””]
Add Sensor (unless already added)
- Select LED color pattern to identify sensor (option list below)
- Set Name for muscle/location
- Sensor configurations are remembered
Monitor and Log Muscle Activation Level
- Set display Zoom
- Configure Biofeedback
- Start Graph
- Data collection runs in background
- End session. Save Graph data.
LED (on M40)
| Pairing | Flashing (72 per minute, about a resting heartbeat) |
| Connected | Slow Flashing (1/3 flash rate) |
[/vc_column_text][vc_custom_heading text=”M40 Identification” font_container=”tag:p|font_size:20px|text_align:left|color:%23111111|line_height:32px” google_fonts=”font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:400%20regular%3A400%3Anormal” css=”.vc_custom_1787147223248{margin-bottom: 3px !important;padding-top: 20px !important;}”][vc_custom_heading text=”By LED Color Pattern” font_container=”tag:p|font_size:18px|text_align:left|color:%23111111|line_height:22px” google_fonts=”font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:300%20light%20regular%3A300%3Anormal” css=”.vc_custom_1787136682060{margin-bottom: 10px !important;}”][vc_column_text css=””]
Color Pattern Options:
- 1. Blue / Blue
- 2. Blue / Green
- 3. Blue / Red
- 4. Blue / White
- 5. Green / Blue
- 6. Green / Green
- 7. Green / Red
- 8. Green / White
- 9. Red / Blue
- 10. Red / Green
- 11. Red / Red
- 12. Red / White
- 13. White / Blue
- 14. White / Green
- 15. White / Red
- 16. White / White
The following options result in LED OFF while M40 is Connected:
- 17. Magenta / Blue
- 18. Magenta / Green
- 19. Magenta / Red
- 20. Magenta / White
- 21. Yellow / Blue
- 22. Yellow / Green
- 23. Yellow / Red
- 24. Yellow / White
[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row]
